Model V
Nextac’s Model V fits standard VTAC closets and louvers, making it a direct VTAC replacement for existing units and a strong option for new construction. It keeps the footprint of a traditional VTAC while updating the design with modern technology. Flexible ducting enables supply and return from multiple directions, while condenser intake and exhaust can be placed at the rear, left, or right—reducing noise and giving you layout freedom.
Powered by a twin rotary BLDC inverter compressor and an integrated ERV, Model V delivers higher efficiency, especially in electric heating and outdoor air use. Unlike wall-mounted units, it installs anywhere and can serve two rooms with separate supply and return. That versatility makes it a modern upgrade and a reliable VTAC replacement for properties seeking better comfort and efficiency without costly redesigns.
Comfort
Cooling Efficiency
Heating Efficiency
Infiltration
Quiet
Venting Flexibility
Fresh Air
Nextac
VTAC
VTHP
User Experience
- Quiet operation (27 dBA)
- Compact format and flexible ducting save space
- Option for washable filters or MERV 8 to MERV 13 rated filters for room air
- Convenient access to MERV 13 filters for outside air
- Auto-restart feature
- Maintains uniform, consistent temperatures
- Backed by a 10-year limited warranty
Operations
- Modes: Cooling, heating, dehumidification, auto
- Fresh air: Provides up to 80 CFM
- Fan speeds: Low, medium, high, auto
- Outside air intake: Programmable
- Exhaust connection: Includes bathroom exhaust option
- Condensate management: Disbursement system for cooling
- Features sound and thermal barriers
- Easy installation-compatible with any standard VTAC closet and louver
- Extraordinarily flexing venting options allow for multiple room air and condenser air configurations.
- Capacity: Wide range in a single unit
Options
- 3,600W electric heating capability staged as 180W +1,800W
- Features a condensate disbursement system for heating
- Airflow: Balanced through AirSync technology
- Power compatibility: Operates on 115V or 230V sources
- Wiring options: Hardwire or LCDI cord
- Refrigerant: Choice of R32 or R410a
Efficiency
- Compressor: Twin rotary BLDC inverter
- Integrated ERV: Uses exhaust air to improve condenser performance for heating and cooling
- Equipped with high-performance ECM axial fans for fresh air intake and stale air exhaust
- Incorporates a unique high-efficiency, high-performance backward ECM centrifugal condenser fan for outside air
- Includes a high-performance ECM centrifugal fan for room supply air
- Heat Exchangers: Extra-large C and V-shaped
- Designed with a sound and thermal barrier for enhanced comfort
- Coils are self-cleaning for minimal maintenance requirements
Controllers
- Onboard touch controller for programing and diagnostics
Optional Controllers
- Wall Mounted Advanced touchscreen with a 7-day program
- Wall Mounted Basic touch controller
- Third party thermostat interface
- BACnet/Modbus interface
- Centralized control system
What's Inside
Technical Specifications
Cooling
Heat Pump
- Maximum (Btu/h)
- Nominal (Btu/h)
- Minimum (Btu/h)
- Input Power (W)
- Efficiency
- Moisture Removal (Pts/h)
95°F
- 24,000
- 20,300
- 4,500
- 1,743
- 13.91 SEER2
- 1.9
105°F
- 22,000
- 18,300
- 3,100
- 1,956
- 9.36 EER2
- -
115°F
- 21,000
- 17,500
- 3,100
- 2,147
- 8.15 EER2
- -
Heating
Heat Pump
- Maximum (Btu/h)
- Nominal (Btu/h)
- Minimum (Btu/h)
- Input (W)
- Efficiency (W)
47°F
- 24,000
- 17,300
- 5,000
- 1,424
- 9.12 HSPF2
17°F
- 12,500
- 10,400
- 4,150
- 1,286
- 2.37COP2
5°F
- 10,100
- 8,300
- 3,850
- 1,210
- 2.01 COP2
0°F
- 8,900
- 7,400
- 3,850
- 1,215
- 1.79 COP2
-5°F
- 8,200
- 6,800
- 3,850
- 1,060
- 1.88 COP2
ERV
General
- Flow type
- Material
- ASHRAE compliance
?
- Counterflow enthalpy exchanger
- Mold and bacteria resistant, washable polymer membrane
- 62.1 And 62.2 When used with the ERV module
Efficiency of core in winter
- Sensible (%)
- Latent (%)
40 CFM
- 83
- 60
60 CFM
- 80
- 55
80 CFM
- 78
- 52
Efficiency of core in summer
- Sensible (%)
- Latent (%)
40 CFM
- 68
- 56
60 CFM
- 64
- 53
80 CFM
- 61
- 50
Filter
- Indoor air (MERV)
- Outside air (MERV)
40 CFM
- MERV 3 / optional MERV 13
- MERV 3 / optional MERV 13
60 CFM
- MERV 3 / optional MERV 13
- MERV 3 / optional MERV 13
80 CFM
- MERV 3 / optional MERV 13
- MERV 3 / optional MERV 13
Leakage
- Internal (WC)
- External (WC)
40 CFM
- 2.4% at 0.40”
- 2.5% at 1.0”
60 CFM
- 2.1% at 0.40”
- 2.3% at 1.0”
80 CFM
- 1.8% at 0.40”
- 2.0% at 1.0”
Airflow
Indoor
- Type
- CFM
- Available ESP
- Speeds
- Filter
?
- ECM centrifugal
- 287 - 710
- 0.6” WC
- Low, med, high, auto
- MERV 3 (optional MERV 13)
Outdoor
- Type
- CFM
- Available ESP
- Intake connection
- Exhaust connection
?
- ECM Centrifugal Backwards
- 410 - 1,150
- 0.7” WC
- 6" round (external exhaust fan is 6.0" diameter)
- 6" round (external exhaust fan is 6.0" diameter)
System
Controls
- Basic functionality
- WiFi
- ADA compliant
- Dry contact
- Power outage restart
?
- Dependent on controller
- Optional module available
- Dependent on controller
- Included
- Auto-on based on last setting
Modes
- Operation
- Restricted modes
- Timers
Condensate
- Pipe (Rubber)
?
- Cool+fresh, cool only, heat+fresh, heat only, auto
- Heat only, cool only, temperature limiting
- Dependent on controller
?
- 3/4" Outside diameter
Electrical
Mechanical Specifications
- Volt range (V)
- Hz/ Phase (Hz/P)
- Power supply
- Power factor (%)
- Input power (standby) (W)
- Input power (off mode) (W)
- Cooling (nominal) (A)
- Cooling (max) (A)
230V
- 180-253
- 60/1
- LCDI power cord or hardwire
- 0.96
- 10.8
- 1.7
- 5.0
- 12.9
Heat Pump Only
- Heating - heat pump only (nom.) (A)
- Heating - heat pump only (max) (A)
Heat Pump + 1,800 W Elec Heat
- Heating - heat pump only (nom.) (A)
- Heating - heat pump only (max) (A)
Motors
230V
- W (max)
- F.L.A.
- HP
- RLA
- LRA
Compressor
- -
- -
- -
- 11.8
- 11.8
Indoor ECM
- 270
- 1.2
- 0.36
- -
- -
Outdoor ECM
- 410
- 1.8
- 0.54
- -
- -
Circuit Breakers
230V
- MCA
- Recommended breaker size
- MOCP
Heat Pump Only
- 17
- 20
- 30
Heat Pump + 1,800 W Elec Heat
- 33
- 35
- 40
LCDI Power Cord
230V
- Amps
- Plug Type
Heat Pump Only
- 15
- 6 - 15P
Heat Pump + 1,800 W Elec Heat
- 20
- 6 - 20P
Sound
?
- dB(A)
- STC
- OITC
- Speeds
Indoor
- 27 - 45
- 40
- 35
- -
Outdoor
- -
- -
- -
- 28 - 56
Dimensions
- Dimensions (Net)
- Weight (Net)
- Cabinet Finish
- Cabinet Material
- 24 W x 27 D x 76” H
- 210 lb
- Black covered with dark gray EPDM
- Steel
Don’t Miss Out – Order Today!
With limited units available for 2026, now is the time to secure your Nextac heat pumps. Click below to preorder and enjoy exclusive savings before it’s too late.
Trusted by leading brands worldwide